Specification
Value
Dimensions (H x W x D) (with bezel)
SFF Drives:
  • 8.59 x 44.55 x 69.22 cm (3.38 x 17.54 x 27.25 in)

LFF Drives:
  • 8.59 x 44.55 x 74.30 cm (3.38 x 17.54 x 29.25 in)

Weight (approximate)
Maximum (all hard drives, power supply, and processor installed):
  • 27.27 kg (60.00 lb)

Minimum (one hard drive, power supply, and processor installed):
  • 21.45 kg (47.18 lb)

Input Requirements (per power supply)
Rated Line Voltage
  • 100 to 120 V ac

  • 200 to 240 V ac

Rated Input Current
  • For 1200 W Power Supply: 10 A (at 100 V ac), 4.9 A (at 200 V ac)

  • For 750 W Power Supply: 8.9 A (at 100 V ac), 4.3 A (at 200 V ac)

  • For 460 W Power Supply: 5.5 A (at 100 V ac), 2.6 A (at 200 V ac)

Rated Input Frequency
  • 50 to 60 Hz

Rated Input Power
  • For 1200 W Power Supply: 930 W (at 100 V ac), 1348 W (at 200 V ac) For 750 W

  • Power Supply: 857 W (at 100 V ac), 824 W (at 200 V ac)

  • For 460 W Power Supply: 526 W (at 100 V ac), 505 W (at 200 V ac)

BTU Rating
Maximum
  • For 1200 W Power Supply: 3530 BTU/hr (at 100 V ac), 4600 BTU/hr (at 200 V ac)

  • For 750 W Power Supply: 2925 BTU/hr (at 100 V ac), 2812 BTU/hr (at 200 V ac) For 460 W

  • Power Supply: 1794 BTU/hr (at 100 V ac), 1725 BTU/hr (at 200 V ac)

Power Supply Output (per power supply)
Rated Steady-State Power
  • For 1200 W Power Supply: 800 W (at 100 V ac), 900 W (at 120 V ac), 1200 W (at 200 to 240 V ac)

  • For 750 W Power Supply: 750 W (at 100 to 120 V ac),750 W (at 200 to 240 V ac)

  • For 460 W Power Supply: 460 W (at 100 to 120 V ac), 460 W (at 200 to 240 V ac)

Maximum Peak Power
  • For 1200 W Power Supply: 800 W (at 100 V ac), 900 W (at 120 V ac), 1200 W (at 200 to 240 V ac)

  • For 750 W Power Supply: 750 W (at 100 to 120 V ac), 750 W (at 200 to 240 V ac)

  • For 460 W Power Supply: 460 W (at 100 to 120 V ac), 460 W (at 200 to 240 V ac)

top

Environmental specifications

Specification
Value
System Inlet Temperature
Operating
10° to 35°C (50° to 95°F) at sea level with an altitude derating of 1.0°C per every 305 m (1.8°F per every 1000 ft) above sea level to a maximum of 3050 m (10,000 ft), no direct sustained sunlight. Maximum rate of change is 10°C/hr (18°F/hr). The upper limit may be limited by the type and number of options installed.
System performance may be reduced if operating with a fan fault or above 30°C (86°F).
Non-operating
-30° to 60°C (-22° to 140°F). Maximum rate of change is 20°C/hr (36°F/hr).
Relative Humidity (non-condensing)
Operating
10 to 90% relative humidity (Rh), 28°C (82.4°F) maximum wet bulb temperature, noncondensing.
Non-operating
5 to 95% relative humidity (Rh), 38.7°C (101.7°F) maximum wet bulb temperature, noncondensing.
Altitude
Operating
3050 m (10,000 ft). This value may be limited by the type and number of options installed. Maximum allowable altitude change rate is 457 m/min (1500 ft/min).
Non-operating
9144 m (30,000 ft). Maximum allowable altitude change rate is 457 m/min (1500 ft/min).