HP EVA P6000 Storage - "Event: 06660006 and Disk Enclosure M6612 Status LED lit as Amber"

Issue

The Disk Enclosure M6612 Status LED lit as Amber, but there is no FAULT status on Disk, Power Supply, FAN, ELMO modules.

Solution

  1. Check P6500 configuration:

    P6500(10000000) There is one -operational state = attention- on Disk ENC#16
    midplane
    firmware = 0021 hardwarerevision = B0
    ......
    objectname = \Hardware\Disk Enclosure 16
    ......
    objecttype = diskshelf
    objectwwn = operationalstate = attention operationalstatedetail = initialized_attention

  2. Analyzed Controller Event Log CEL:

    2012-Jan-02 04:10:45 06660006; A controller has detected a change in the Enclosure midplane condition.
    Reason: Enclosure Vendor Identification: HP ; Enclosure Product Identification: D2600 SAS AJ832A; Enclosure Product Revision: 0131; Enclosure Saleable
    Serial Number: CN800803BX ; Updated Condition: NONCRITICAL; Enclosure WWID (node): 5001438006cb7f3c; Loop B ELMo WWID (port): 5001438006cb7f3d; Enclosure: 16;

    2012-Jan-02 04:10:00 065a0006; A controller has detected a change in a Enclosure condition.
    Reason: Enclosure Vendor Identification: HP ; Enclosure Product Identification: D2600 SAS AJ832A; Enclosure Product Revision: 0131; Enclosure: 16; Updated Condition: NONCRITICAL;
    Extra: Enclosure WWID (node): 5001438006cb7f3c; Enclosure Number: 16; Loop B ELMo WWID (port): 5001438006cb7f3d;

  3. Analyzed ELMO events:

    ELMO log entries :
    2012-Jan-02 04:09:24
    Entity : Midplane logic (0x12)
    Event : SES Status (0x01),
    Meaning : Element Index = 1; Status = Noncritical (3); Byte 1 = 0; Byte 2 = 0; Byte 3 = 0;
    Status Changes : Status[ (1) --> Noncritical (3)];

  4. This issue was resolved by replacement of Backplane of Disk Enclosure.

Provide feedback